Serial protocol




Дата канвертавання24.04.2016
Памер15.87 Kb.
SERIAL PROTOCOL
This document describes how to communicate with a Meridian G68 Surround Controller via the serial port.
Rear Serial Port Pinout for the Meridian G68

Purpose

PIN

PURPOSE

DB9 - Female

1

Not Used




2

Transmit

3

Receive

4

Not Used

5

Ground

6

Not Used

7

Not Used

8

Not Used

9

Not Used


Rear Serial Port Settings for the Integra CD Player

Parameter Value

PARAMETER

VALUE

Baud

9600

Data Bits

8

Stop Bits

1

Parity

None

Flow Control

None


For connection to the Xantech MRC-88
Connection to the rear serial port requires a male to male NULL MODEM serial cable. It is recommended that the RS-232 cable be 25 feet or less.
For connection to the SmartPAD LCD touch panel

(NOTE: Requires the RS422232 module with 781RG power supply)
Connection to the rear serial port requires a female to male standard straight through serial cable (no null modem required). It is recommended that the RS-232 cable be 25 feet or less.
For connection to the Xantech RS2321X8 Serial Router
Connection to the RS232 serial ports requires a male to male NULL MODEM serial cable. Connection to the RS422 serial ports requires the RS422232 module with 781RG power supply and a female to male standard straight through serial cable (no null modem required). It is recommended that the RS-232 cable be 25 feet or less.