List of parameters




Дата канвертавання25.04.2016
Памер32.17 Kb.

RMS PAR-EX1

LIST OF PARAMETERS

R M S - EX 1







Contents


Contents 2

UNITS 2


LDU-RM1 2

CMD-RM2 3

CMI-RM1 3

VIM-RM1 4

MPM-RM1 / MPM-RM2 4

TVD-RM3 4

POM-RM1 5

HPM-RM1 5

OTM-RM1 / 1 5

OTM-RM1 / 2 5

EX-1 (Option unit) 6

EX-2 (Option unit) 6

EX-3 (Option unit) 6

CONTACT 6





UNITS


Unit Description Serial no. HW rev. SW rev.

Refiner Valmet RGP-? R?

RMS-EX1 RMS Rack ? 2.0

LDU-RM1 Display Control Unit RMS-SD ? 5.0 4.6

CMD-RM2 Control Motor Driver ? 6.2

CMI-RM1 Control Motor Interface ? 6.1 4.2

VIM-RM1 Vibration Monitor ? 8.1

MPM-RM2 Motor Power Monitor ? 3.0 1.1

TVD-RM3 Touchpoint Monitor ? 7.1

POM-RM1 Position Monitor ? 9.0

HPM-RM1 Hydraulic Pressure Monitor ? 4.2

OTM-RM1 (1) Oil Temperature Monitor ? 7.1

OTM-RM1 (2) Oil Temperature Monitor ? 7.1

LDU-RM1


Menu

parameter description actual default max step type

F1rA Range

PoEr Power - 5.0 50.0 1/2/5 MW

FdPL FG piston length - 1.0 5.0 0.1 mm

FdSd FG safe distance - 1.0 5.0 0.1 mm

Fdto FG timeout - 10 30 1 s

PoSL POT stroke length - 50.00 200 10 mm

HP_A Hydraulic pressure A - 50.0 150.0 0.5 ton

HP_b Hydraulic pressure B - 50.0 150.0 0.5 ton

FrbF FG dist. before reset - - 50.00 - mm

FrAF FG dist. after stepping - - 50.00 - mm

FrdI FG result POM - - 50.00 - mm

ErCE Electronic RMC enable - 0 1 1 1 = RMC

dISP External display unit - 1 2 1

--------------------------------------------------------------------------------------------------------------------------------

This menu is only shown if the parameter “ErCE” above is set to “1”.

F2Pr Production

PrPo Prod. Position Offset - 2.00 20.00 0.10 mm

PrPS Prod. Pos. manual Set - 0.00 50.00 0.10 mm

PrLP Prod. Limit Power - 50 100 1 %

PrLt Prod. min Limit Time - 10 600 1 hours

PrP0 Prod. Pos - 0 (latest) - 0.00 50.00 0.01 mm

PrP1 Prod. Pos - 1 - 50.00 - mm

… … … … …

PrP9 Prod. Pos - 9 (oldest) - 50.00 - mm

Potr Pos Transd. Reversed - 0 1 1 (1 = Reversed )

--------------------------------------------------------------------------------------------------------------------------------

This menu is only shown if the parameter “ErCE” above is set to “1”.



F3tP Touch Point

tPLE TP Level - 40 100 5 %

tPtI TP Time - 0.5 5.0 0.5 s

tPFU TP Function - 1 2 1 (2= Auto)

tPP0 TP Pos - 0 (latest) 50.00 - mm

tPP1 TP Pos -1 50.00 - mm

… … … … … …

tPP9 TP Pos -9 (oldest) 50.00 - mm

--------------------------------------------------------------------------------------------------------------------------------

This menu is only shown if the parameter “ErCE” above is set to “1”.



F4PL Plate wear

PLrE Plate wear reset - 1 2 1 (1 = Normal)

PLoF Plate wear offset - 50.00 50.00 0.01 mm

PLdI Plate wear amount Calculated by LDU 0.01 mm




CMD-RM2


DIP settings actual default function

4-pole dip switch in the front left right left right

1. Drive 1     Drive current 1

2. Drive 2     Drive current 2

3.     Not used

4. Hold     Hold current


CMI-RM1


Dip settings actual default

Function off on off on

Pitch of thread SW2/1    

Pitch of thread SW2/2    

CMD-card SW2/3    

Direction SW2/4    

Speed adjustments actual default adjustable range

High speed (H_sp) - 100 % 50 - 150

Low speed (L_sp) - 100 % 50 - 150

VIM-RM1


Limit adjustments actual default adjustable range

Limit 1 (L 1) - 10 mm/s 0 - 25

Limit 2 (L 2) - 8 mm/s 0 – 25

MPM-RM1 / MPM-RM2


The nominal motor power is configured in the LDU-unit. See the PROGRAMMING MANUAL, PRO-EX1.

Dip settings MPM -RM2 actual default

off on off on

Use Limit 3 (Float) SW4/1     Set to off if not used

Not used SW4/2    

Not used SW4/3    

Not used SW4/4    

Limit adjustments actual default adjustable range

Low (L 1) - 20 % of P 0 - 100 % of P

Lowlow (L 2) - 10 % of P 0 - 100 % of P

Floating (L 3 LEVEL) - 20 % of P 0 - 100 % of P

Floating (L 3 TIME) - 3.0 s

Limit 3 (Floating) is only available P is the programmed nominal motor

for the MPM-RM2 unit. power in the LDU-unit


TVD-RM3


Dip settings actual default

Transducer type setting off on off on

SW5/1    

SW5/2    

SW5/3    

SW5/4    

Transducer location attenuation off on off on

SW3/1    

SW3/2    

SW3/3    

SW3/4    

Low gain attenuation off on off on

SW4/1    

SW4/2    

SW4/3    

SW4/4    

Headset volume off on off on

SW2/1    

SW2/2    

Limit adjustments actual default adjustable range

Limit 1 (L 1) - 75 % 0 - 100 %

Limit 2 (L 2) - 50 % 0 - 100 %



POM-RM1


Limit adjustments actual default adjustable range

Limit 1 (L 1) - 39.00 mm 0 - 50

Limit 2 (L 2) - 30.00 mm 0 - 50

Limit 3 (L 3) - 28.00 mm 0 - 50


HPM-RM1


Limit adjustments actual default adjustable range

Ch 1, Limit 1 (A-chamber) - 40 % of A 0 - 100 % of A

Ch 1, Limit 2 (A-chamber) - 20 % of A 0 - 100 % of A

Ch 2, Limit 1 (B-chamber) - 40 % of B 0 - 100 % of B

Ch 2, Limit 2 (B-chamber) - 20 % of B 0 - 100 % of B

The readings are in percent of programmed nominal A-chamber and B-chamber pressure in the LDU-unit.


OTM-RM1 / 1


Dip settings actual default (100C)

off on off on

SW2/1    

SW2/2    

SW2/3    

SW2/4    

All 4 must either be off or on: 100 °C - set all to off, 200 °C - set all to on.

Limit adjustments actual default (100°C) adjustable range (100°C)

Channel 1, Limit 1 (C1L1) - 60 °C 0 -100

Channel 1, Limit 2 (C1L2) - 55 °C 0 -100

Channel 2, Limit 1 (C2L1) - 60 °C 0 -100

Channel 2, Limit 2 (C2L2) - 55 °C 0 -100


OTM-RM1 / 2


Dip settings actual default (100C)

off on off on

SW2/1    

SW2/2    

SW2/3    

SW2/4    

All 4 must either be off or on: 100 °C - set all to off, 200 °C - set all to on.

Limit adjustments actual default (100°C) adjustable range (100°C)

Channel 1, Limit 1 (C1L1) - 60 °C 0 -100

Channel 1, Limit 2 (C1L2) - 55 °C 0 -100

Channel 2, Limit 1 (C2L1) - 60 °C 0 -100

Channel 2, Limit 2 (C2L2) - 55 °C 0 -100



EX-1 (Option unit)


Dip settings actual default

off on off on

SW /1    

SW /2    

SW /3    

SW /4    

Limit adjustments actual default

Channel 1, Limit 1 -

Channel 1, Limit 2 -

Channel 2, Limit 1 -

Channel 2, Limit 2 -

EX-2 (Option unit)


Dip settings actual default

off on off on

SW /1    

SW /2    

SW /3    

SW /4    

Limit adjustments actual default

Channel 1, Limit 1 -

Channel 1, Limit 2 -

Channel 2, Limit 1 -

Channel 2, Limit 2 -

EX-3 (Option unit)


Dip settings

actual default

off on off on

SW /1    

SW /2    

SW /3    

SW /4    

Limit adjustments

actual default

Channel 1, Limit 1 -

Channel 1, Limit 2 -

Channel 2, Limit 1 -

Channel 2, Limit 2 -

CONTACT


Sales, development, production and service:
Dametric AB

Jägerhorns Väg 19, 141 75 Kungens Kurva, Sweden

Phone: +46-8 556 477 00 Telefax: +46-8 556 477 29

e-mail: service@dametric.se Web site: www.dametric.se




July 31, 2014 ()