6.16 CRA-I031: (input) Metering System Data


Interface ID:

CRA-I031


Source:

BSC Party



Title:

Metering System Data



BSC reference:

CRA SD 6.4, CRA BPM 3.3, ERM, CRA BPM 4.9, RETA SCH 4,B, 2.4.2, CP569, CP753, CP756



Mechanism:

Manual, by email, letter or fax, or can be sent as an electronic data file over the network



Frequency:

As Necessary



Volumes:

Low

The CRA shall receive Metering System Registration Details. The CRA records the master set of registration details for the Metering Systems. This information is later augmented by the CDCA to record the full details for NETA. The information shall include the following:
Action Description
Authentication Details

Name


Password
Metering System Details

Metering System Identifier

Meter Operator Agent ID

Effective From Date

Effective To Date

Transfer flag (indicates this is a transfer from SMRS)


For each new Metering System registration, the Registrant shall include confirmation that either:

  • The Registrant is the Equipment Owner, or

  • The Registrant has obtained the Equipment Owner’s consent for the appointment.




Physical Interface Details:

A physical structure is defined for this manual interface because the registrant can send this information (except for the equipment owner’s confirmation for new registrations) as an electronic data file over the network; the CRA operator enters the information via a screen-based interface however it is sent.




6.17 CRA-I034: (input) Flexible Reporting Request


Interface ID:

CRA-I034


Source:

BSCCo, BSC Party, BSC Party Agent, SO, BSC Service Agents



Title:

Flexible Reporting Request



BSC reference:

CR 53, P8, CP756



Mechanism:

Manual, by email, letter or fax



Frequency:

As Necessary



Volumes:

Low


Interface Requirement:

The CRA shall receive authorisations:

a) to start or stop sending copies of reports generated for one organisation to another organisation

i) a BSC Party (P) may receive copies of reports generated for another BSC Party (P’). The request must be submitted by BSCCo or, for those reports designated by BSCCo, by BSC Party P.

ii) BSCCo may receive copies of reports generated for any organisation. The request must be submitted by BSCCo.

b) to specify which version of a report to create for an organisation (If present this requests a specific version of the report be generated for the party. The default is to issue the latest version of a report. Old versions of reports are supported for a limited period (as agreed between the BSC Service Agent providing the report and BSCCo Ltd) following the introduction of a new version) The request will come from the organisation;

Requesting BSC Party Details

organisation Id

organisation type
Report Copy Details

Report Type

Effective from date

Effective to date

organisation Id

organisation type

Start/Stop Flag
Report Version Details

Report Type

Effective from date

Effective to date

Version (specific or “latest”)
Note: If receiving a copy of another party’s report, the version copied will be the version generated for the original party

Note: in this specification, “organisation” is any ofBSCCo, BSC Party, BSC Party Agent, SO, BSC Service Agents



Physical Interface Details:

The flow may contain requests from one or more organisation and each request may cover a number of report types/BSC Parties.




6.18 CRA-I038: Transfer from SMRS information


Interface ID:

CRA-I038


Source:

Transfer Coordinator, BSC Party



Title:

Transfer from SMRS information



BSC reference:

CP753


Mechanism:

Manual


Frequency:

On Demand



Volumes:

low


Interface Requirement:

Where metering is transferred from SMRS into CRA, the following information will be provided.


Status (New, rejected, confirmed, confirmation request)

Effective from date (if confirmed)

Name of Registrant

Address


Contact for Transfer

Telephone number

Email address

Participant ID

Site name

Site address


Transfer details

Circuit description

Measurement quantity

Metering System ID

Metering Subsystem ID
Metering system details

NGC BMU identifiers

BM Unit identifier

GSP reference

CVA MOA


Physical Interface Details:

The flow will include a schematic diagram where appropriate