Idd part 1 Interfaces with bsc parties and their Agents




старонка58/82
Дата канвертавання24.04.2016
Памер4.34 Mb.
1   ...   54   55   56   57   58   59   60   61   ...   82

5.28 CDCA-I038: (output) Reporting metering system faults


Interface ID:

CDCA-I038



User:

MOA, BSC Party



Title:

Reporting metering system faults.



BSC reference:

CDCA SD 11.1-11.4

BPM


Mechanism:

Manual


Frequency:

As required



Volumes:

estimate 10 per day (0.2% of 5000)



Interface Requirement:

The CDCA reports to the MOA and the BSC party who is responsible for the meter (the Registrant) all suspected metering faults detected while performing its responsibilities. This will include details of the fault. Note that the faults reported may relate to exception reports for missing or invalid meter period data (CDCA-I010).





Physical Interface Details:





5.29 CDCA-I041: (output) Interconnector Aggregation Report


Interface ID:

CDCA-I041



User:

IA


Title:

Interconnector Aggregation Report



BSC reference:

CDCA SD 19.3, B

CDCA BPM 4.4

BPM IRR CDCA5, CP559



Mechanism:

Electronic data file transfer



Frequency:

Daily, per aggregation run



Volumes:

Initially 96 (2 interconnectors * 48 readings). The number of interconnectors is expected to increase to 5 or 6.




Interface Requirement:

A report on aggregated meter flow volumes for each Interconnector is sent to the BSC party who is the Interconnector Administrator associated with the Interconnector.


The following information is sent:
Interconnector Id

Settlement Date

Settlement Run Type

CDCA Run Number

Date of aggregation

Settlement Period

Estimate Indicator (T/F)

Meter Volume

Import/Export indicator (I/E)
The Import/Export indicator indicates the direction of the energy flow: the Meter Volume is therefore unsigned.



Physical Interface Details:


5.30 CDCA-I042: (output) BM Unit Aggregation Report


Interface ID:

CDCA-I042



User:

BSC Party

System Operator


Title:

BM Unit Aggregation Report



BSC reference:

CDCA SD 22, 23.1, A, B

CDCA BPM 4.4

BPM IRR CDCA3, CP559



Mechanism:

Electronic data file transfer



Frequency:

Daily, per aggregation run



Volumes:


Interface Requirement:

A report on aggregated meter flow volumes for each BM Unit is sent to the BSC party who is the lead party for the BM Unit, and copied to the System Operator.


The following information is sent:
BM Unit Id

Settlement Date

Settlement Run Type

CDCA Run Number

Date of aggregation

Settlement Period

Estimate Indicator (T/F)

Meter Volume

Import/Export Indicator (I/E)
The Import/Export indicator indicates the direction of the energy flow: the Meter Volume is therefore unsigned.



Physical Interface Details:




5.31 CDCA-I044: (input) Meter System Proving Validation


Interface ID:

CDCA-I044



Source:

MOA


Title:

Meter System Proving Validation



BSC reference:

CDCA SD 7.3, CP756




Mechanism:

Manual, by email, letter or fax



Frequency:


Volumes:



Interface Requirement:

The MOA will confirm that the data from meter system proving is valid.



Physical Interface Details:




1   ...   54   55   56   57   58   59   60   61   ...   82