5.12 CDCA-I012: (output) Report Raw meter Data


Interface ID:

CDCA-I012



User:

BSC Party, Distribution Business, System Operator



Title:

Report Raw meter Data



BSC reference:

CDCA SD 19.1

CDCA BPM 4.21, CP841


Mechanism:

Electronic data file transfer



Frequency:

Daily


Volumes:

up to 240000 period readings to each agent

(5000 * 48)


Interface Requirement:

The CDCA provides the relevant BSC Party(s), including the Distribution Business, and the System Operator, with a Metering System data collection report relating to the raw meter period data collected from each meter or associated outstation.
The readings will not include any estimated data. All readings reported will not be line loss adjusted. The report will report data in clock time.
The data included, for each BSC Party will consist of those Metering Systems for which the BSC Party is the Responsible Party, and will consist of:
BSC Party Identifier

Metering System Identifier

Settlement Date

Outstation Id

Channel Number

Measurement Quantity (Active Import , Active Export, Reactive Import, or Reactive Export)

Main/Check Indicator

Settlement Period (46, 48 or 50 occurrences)

Meter Reading Volume

Meter Reading Status


Meter Reading Status can be one of:

A - Valid meter data

B - Invalid meter data

C - Unavailable meter data

D – Substituted from secondary outstation meter data


Note that there may be more than one Check channel for the same Main, for a given Measurement Quantity.
This report is also sent to the System Operators, covering all metering systems.


Physical Interface Details:





5.13 CDCA-I013: (input) Response to Estimated data


Interface ID:

CDCA-I013



Source:

BSC Party



Title:

Response to Estimated data



BSC reference:

CDCA SD 10.8

CDCA BPM 4.22?

CP566, CP756



Mechanism:

Manual, by email, letter or fax



Frequency:

Daily


Volumes:

estimate 50 per day (1% of 5000)



Interface Requirement:

BSC Parties will respond to CDCA-I037 ‘Estimated Data Notification’ messages, indicating their agreement to an estimate made when meter readings are unavailable.


The flow contains at minimum:
Metering System Identifier

Settlement Date

Outstation Id

Channel Number

Measurement Quantity (Active Import , Active Export)

Settlement Period (46, 48 or 50 occurrences)

Agreement Flag (A/P)

Estimated Meter Reading Volume (Agreed estimate or Proposed value for estimate)

Basis for proposed value


Physical Interface Details:





5.14 CDCA-I014: (output) Estimated Data Report


Interface ID:

CDCA-I014



User:

BSC Party, MOA, BSCCo Ltd, System Operator



Title:

Estimated Data Report



BSC reference:

CDCA SD 10.7, 10.9, CP751, CP841, CP1245



Mechanism:

Electronic data file transfer



Frequency:

As required



Volumes:

estimate 50 per day (1% of 5000)



Interface Requirement:

The estimated data report contains all estimate notifications issued by CDCA in a given period.


An estimated data report is sent to:

1. BSCCo Ltd (on request) - data for all metering systems

2. MOA (Daily) - data for metering systems operated by the MOA

3. BSC Party (Daily) - data for metering systems for which the party is the responsible party.

4. the host Distribution business or the Transmission Company , depending who has registered the metering system (Daily).
This report will be run at the end of the working day to report estimates carried out on that day.
The information provided is as follows for each Metering System included in the report:
Total Volume Estimated in Report

BSC Party Identifier

Metering System Identifier

Settlement Date

Outstation Id

Channel Number

Meter Serial Number

Measurement Quantity (Active Import , Active Export)

Settlement Period (46, 48 or 50 occurrences)

Original Meter Reading Volume (if available)

Estimated Meter Reading Volume

Estimation Method

Estimate Agreed Indicator (T/F)
Estimation method is an indicator of the method used for estimation:

A - Generation: Main meter data missing or incorrect in Primary and Secondary Outstations, Check meter data available – copied from Primary Check

D - Demand: Main meter data missing or incorrect, Check meter data available – copied from Primary Check

E - Demand: Main meter data missing or incorrect, Check meter not fully functional, but Main meter or Check meter register advance available – profiled using Meter Reading Estimation Tool

I - Demand: Main meter data missing or incorrect, Check meter not fully functional, Main meter and Check meter register advance NOT available – profiled using Trend

J - Generation: Main meter data missing, or incorrect, in Primary Outstation, Secondary Outstation main meter data available – substituted from Secondary Main

K - Generation: Main and Check meter data missing or incorrect in Primary and Secondary Outstations, data estimated to zero awaiting confirmation of generation

L - Demand; Primary Main meter data missing, or incorrect, Secondary Outstation Main meter data available – substituted from Secondary Main

M - Demand: Main meter data missing or incorrect, data copied from suitable settlement period(s)

N - Validation Failure: Main meter data deemed correct

U - Used parties own reading

X - Used different estimation method